Three concentric pipes put on a suitable
stand make up the equipment. A lagging substance is used to fill the spaces
between the innermost and middle pipes, and another lagging material is used to
fill the spaces between the middle and outermost pipes. A cartridge heater is
installed at the pipe's axle length to heat the lagged pipe. The input to the
heater can be measured using the voltmeter and ammeter on the panel. The
thermocouples affixed to the pipe's surfaces can measure the intermediate
temperatures. So, it is possible to determine the materials' final
conductivity.
SPECIFICATIONS:
a)Gl pipe (innermost) – 6 cm. (Outer Diameter).
b)
Gl Pipe (Middle) – 8.5 cm. (Mean Diameter)
c)G! Pipe (Outermost) – 10.7 cm. (inner Diameter)
d)Length of pipes 1 Meter.
a)Single Phase Dimmerstat – 1 No.
b)Voltmeter (0 – 250V) – 1 No.
c)Ammeter (0- 2A) – 1 No.
Multichannel Digital Temperature Indicator ranging (0 – 300 C) using
Cr/AI Thermocouples
Services Required: