Heat pump is a
device to pump heat from one source to another. The heat obtained by heat pump
is more than that could be obtained by direct electrical heating. The apparatus
consists of refrigeration system with water cooled shell and coil type
evaporator and condenser.
Specifications:
1.compressor –
hermetically sealed compressor using r-12 refrigerant, having capacity 0.3 tons
of refrigeration. Condensing pressure – max. 15 kg/cm2 (actual pressures will
depend upon working conditions).
2.condenser –
shell and coil type with continuous water flow arrangement.
3.evaporator –
shell and coil type with continuous water flow arrangement.
4.expansion
valve – internally equalized thermostatic expansion valve.
5.measurements
–
a) rotameter for condenser & evaporator
water flow rate measurement.
b) rotameter for liquid refrigerant flow
measurement.
c) pressure gauges for condensing and
evaporating pressure – 2 nos.
d) thermometer for refrigeration cycle &
water temp, measurement – 7
e) wattmeter for compressor input
measurement.
f) ammeter for compressor current
measurement.
6.controls
a) hp/lp cutout for compressor.
b) overload protector for compressor.
c) gate valve to control water flow rates.
d) necessary switches and fuse.
A technical
manual is accompanies the unit.
Utilities required other than above supply:
1.floor
surface area – 2m, x 2m. X 1.5m. Height.
2.220v. 15amp.
Single phase stabilized power supply.